Agents chimiques secs

NFPA Global Solutions fournit des essais et la certification de produits pour les agents chimiques secs d'extinction d'incendie, garantissant le respect des normes de performance en matière de sécurité incendie.

Nous proposons des analyses de teneur en humidité et de composition chimique pour les agents chimiques secs. La NFPA exige que les agents chimiques secs soient minutieusement vérifiés afin de contrôler leur type, leur contamination et leur état avant toute réutilisation ou recharge.

Why Dry Chemical Agent Compliance Matters

Dry chemical agents are a critical component of many fire suppression systems, but moisture, contamination, vibration, temperature fluctuations, and storage conditions can affect their physical properties over time. These changes may lead to caking, clumping, reduced flowability, and impaired system performance during a fire event.

Dry chemical testing provides objective data on agent condition, helping identify deterioration, contamination, or other performance concerns. Results support maintenance, replacement, and system reliability decisions, while helping organizations maintain compliance with applicable NFPA inspection, testing, and maintenance requirements. Periodic testing can identify potential issues before an emergency occurs, supporting fire protection readiness, system reliability, and life safety objectives.

Dry Chemical Agent Testing Overview

NFPA standards require that dry chemical fire suppression systems be maintained and inspected to confirm the extinguishing agent remains in a serviceable condition throughout its operational life. Moisture intrusion, vibration, contamination, improper storage, and age can affect agent properties, potentially impacting system performance during a fire event.

Periodic laboratory testing helps verify that dry chemical agents continue to meet the manufacturer's specifications and applicable standards for chemical composition and moisture content. Testing provides objective data to support maintenance decisions, regulatory compliance, and confidence that the system will perform as intended when needed.

Key Capabilities Include:

  • Comprehensive agent analysis to evaluate critical performance characteristics, including moisture content and chemical composition.
  • Independent laboratory testing performed by experienced fire protection testing professionals using established test procedures to help determine whether the agent remains suitable for continued service.
  • Actionable test reports that provide clear results and recommendations, helping system owners, contractors, and authorities having jurisdiction make informed maintenance and compliance decisions.

Free Dry Chemical Agent Sample Kits

Standard Turnaround: 5-business days

Expedited Testing Available: Contact us for pricing.

Quantity Needed

1 kit = 1 sample

2 kits = 2 samples

3 kits = 3 samples

Applicable Testing

  1. IMO 1432 for Fire Protection Systems
  2. NFPA 17 for Fixed Dry Chemical Systems
  3. NFPA 10 for Portable Fire Extinguishers

Kit Includes

  • 1 moisture-proof 60 ml sample container
  • Foam packing material
  • Pen to label sample container
  • Sample return form (online available and preferred)
  • UPS Ground return label (in the contiguous US)

Shipping Information

Ground shipping to you is included, as well as return labels (UPS/USPS) within the contiguous United States (limited free 1-way shipping to Alaska, Hawaii, Puerto Rico, and Canada; inquire for details). Expedited shipping is available at your cost.

How Dry Chemical Agent Testing Reduces Risk and Supports Compliance

Dry Chemical Agent Testing helps reduce risk by verifying that fire suppression agents remain in serviceable condition and capable of performing as intended during a fire event. Over time, dry chemical agents can become contaminated, absorb moisture, compact, or experience chemical degradation that may impact flow characteristics, discharge performance, and extinguishing effectiveness. Left unchecked, these conditions can compromise system reliability and increase the risk of suppression system failure when protection is needed most.

Laboratory analysis provides objective data on critical agent properties, including moisture content, chemical composition, and overall condition. This information allows owners, contractors, and facility managers to make informed maintenance, recharge, replacement, and lifecycle management decisions before performance issues affect system operation. Testing also supports compliance with applicable NFPA requirements, including NFPA 17, which requires periodic evaluation and maintenance of dry chemical extinguishing systems, and NFPA 10 requirements related to the condition and serviceability of dry chemical extinguishing agents.

By proactively identifying agent degradation, contamination, or other performance concerns, Dry Chemical Agent Testing helps protect system reliability, support regulatory compliance, and ensure fire suppression systems remain ready to perform when called upon to protect life and property.

Dry Chemical Agent Accreditations

Dyne is ISO 9001 Certified

Relevant Dry Chemical Agent Standards and Test Methods

  • NFPA 10 Portable Fire Extinguishers 
  • NFPA 17 Dry Chemical Extinguishing Systems
  • IMO 1432 
  • ISO 7202 Fire protection – Fire extinguishing media – powder
  • OSHA 29

What types of Dry Chemical Agent samples are tested?

We test all types of dry chemical (ABC, BC/Regular, Purple K, etc.)

How many ml or ounces are required for testing?

Our dry chemical kit contains a 60 ml moisture-proof sample container. Please make sure your sample fills the container so testing can be completed properly. If you are not using our sample kit, please send a sample that is equal to or greater than 60 ml.

How are test results delivered?

Test results are delivered via email within 5 business days or less from the receipt of the sample(s).  

Who should I contact to get started?

You can contact our lab directly to discuss your testing needs at 800-632-2304.

Le contenu de l'accordéon apparaîtra ici

For more information, please review our Legal Notice page. 

Why NFPA Global Solutions Dry Chemical Agent Testing

Dyne Fire Protection Labs, an NFPA Global Solutions Company, provides independent laboratory testing for dry chemical fire suppression agents used in fire protection systems. Over time, moisture exposure, caking, contamination, vibration, and aging can affect agent performance. Laboratory testing helps verify that the dry chemical agent continues to meet the manufacturer's specifications and remains capable of proper discharge and fire suppression performance when needed.

Our testing services evaluate critical agent characteristics, including moisture content and chemical composition. The resulting data provides system owners, contractors, and authorities having jurisdiction with objective information to support maintenance, compliance, and system reliability decisions.

Testing Advantages:

  • Test reports in 5 business days or less (with rush 24-hour turnaround available)
  • Convenient sample collection kits available upon request
  • Free shipping within the contiguous United States (limited free one-way shipping to Alaska, Hawaii, Puerto Rico, and Canada; inquire for details)
  • Comprehensive laboratory reports with clear findings and recommendations
  • Online access to results and return forms
  • Direct communication with our quality technicians and customer service staff

In addition to evaluating an agent's current condition, testing can be used to establish a performance baseline, support maintenance programs, and verify the effectiveness of corrective actions taken after contamination, moisture intrusion, or other service-related concerns. This can provide continued confidence in the readiness and reliability of dry chemical fire suppression systems.

Order Your Dry Chemical Agent Kit  

Request your free Dry Chemical Agent sample kit and connect with our team to discuss your testing needs. We can help determine sample requirements, answer questions about the testing process, and provide guidance on submitting samples for evaluation. If you have questions, contact us at (800) 632-2304 or dyne.lab@nfpaglobal.com.